Difference between revisions of "Battery backup"

From Yantrr Wiki
Jump to: navigation, search
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
VIBE2 provides an optional battery circuit for standby purposes.
 
VIBE2 provides an optional battery circuit for standby purposes.
  
=='''INSTRUCTIONS'''==
+
==Instructions==
  
 
A 2-pin Connector interface is provided at battery test points TP6 and TP8, with a 10K thermistor R31 mounted on PCB to simulate the thermistor circuit for battery charging.
 
A 2-pin Connector interface is provided at battery test points TP6 and TP8, with a 10K thermistor R31 mounted on PCB to simulate the thermistor circuit for battery charging.
 
  
 
Following is a diagram explaining the battery interfaces on VIBE2 :
 
Following is a diagram explaining the battery interfaces on VIBE2 :
Line 15: Line 14:
  
 
*  Connect a 3.7V Li-Po battery of sufficient capacity with its VBAT to TP6 and GND to TP8.
 
*  Connect a 3.7V Li-Po battery of sufficient capacity with its VBAT to TP6 and GND to TP8.
 
  
 
*  Issue the following commands in console :
 
*  Issue the following commands in console :
 
  
 
a) Change battery charging range to 0-60 degree C
 
a) Change battery charging range to 0-60 degree C
 
  # i2cset -f -y 0 0X24 6 0Xb3 b
 
  # i2cset -f -y 0 0X24 6 0Xb3 b
 
  
 
b) Change battery charging voltage to 4.2V
 
b) Change battery charging voltage to 4.2V
 
  # i2cset -f -y 0 0X24 5 0Xa0 b
 
  # i2cset -f -y 0 0X24 5 0Xa0 b
 
  
 
'''NOTE:''' When board is powered up only by battery then Power switch S3 has to be pressed to turn it on.
 
'''NOTE:''' When board is powered up only by battery then Power switch S3 has to be pressed to turn it on.
 
  
 
Please refer to image provided below for battery connections
 
Please refer to image provided below for battery connections
 
  
 
[[File:IMG_22381.JPG|700px]]
 
[[File:IMG_22381.JPG|700px]]

Latest revision as of 05:28, 12 July 2016

VIBE2 provides an optional battery circuit for standby purposes.

Instructions

A 2-pin Connector interface is provided at battery test points TP6 and TP8, with a 10K thermistor R31 mounted on PCB to simulate the thermistor circuit for battery charging.

Following is a diagram explaining the battery interfaces on VIBE2 :


VIBE2 battery.jpg


Follow the given steps to change the battery charging conditions :

  • Connect a 3.7V Li-Po battery of sufficient capacity with its VBAT to TP6 and GND to TP8.
  • Issue the following commands in console :

a) Change battery charging range to 0-60 degree C

# i2cset -f -y 0 0X24 6 0Xb3 b

b) Change battery charging voltage to 4.2V

# i2cset -f -y 0 0X24 5 0Xa0 b

NOTE: When board is powered up only by battery then Power switch S3 has to be pressed to turn it on.

Please refer to image provided below for battery connections

IMG 22381.JPG