Overview
Quick Start Guide
Board Layout
Jumpers
Jumper | Description |
---|---|
J2 | Battery connection bypass jumper, for non BATT-UPG configurations this jumper should be closed. |
J3 | Boost section bypass jumper, for non BATT-UPG configurations this jumper should be closed. |
Switches
Switch | Description |
---|---|
S1 | Reset switch |
S2 | Boot switch |
S3 | Power switch |
S4 | Modem ON/OFF switch |
S5 | Modem Reset switch |
S7 | Cape address switch |
LEDs
LED | Description |
---|---|
D1 | Power LED |
D2 | User LED 0 |
D3 | User LED 1 |
D4 | User LED 2 |
D5 | User LED 3 |
D13 | Modem Power LED |
D14 | Modem operation status LED |
D15 | Modem network activity status LED |
D16 | Modem network registration mode LED |
D18 | Cape Side Power LED |
D20 | Diagnostic status LED |
Getting Started
Setting up the system
- Place 3V coin cell(supplied with VIBEQ) in the holder for RTC.
- Place a data enabled mini-SIM in the SIM card slot and connect a GSM antenna to the respective main antenna connector using uFL connectors.
- Ensure that the power jumpers J2 and J3 on VIBEQ are in place and eeprom address set at 0x54 using dip switch S7
- Power up VIBEQ using the 5V,5A DC adapter (supplied with VIBEQ).
|
Before proceeding further ensure D1 LED is glowing properly. Make sure that the adapter being used is of proper rating and has been connected properly. |
|
Before powering down the system always ensure to Turn OFF the Modem using the PWRKEY turn ON/OFF control pin or using the AT Command AT+QPOWD. |